WPD FS SENSUS

Turbine flow converter (meter) of hot water

Hot water flow converters (meters) turbine flanged WPD FS are used to measure the volume of hot water with a maximum temperature of up to 130 °C (short-term up to 150 °C for 1 hour or a day) and a working pressure of up to 1.6 MPa, as well as as a component of mechanical heat energy meters or cold metering. Volume measurement at high rates with exceptional overload resistance.

Brief characteristics
Measurement typeMechanical
ConnectionDN 15 - 40 mm
Accuracy class3 (DN 15 - Ду 20 mm), 2 (DN 25 - DN 40 mm)
The qp/qi ratio1:50, to order - 1:100
Water temperature (heat transfer)130°C
ProtectionIP54
Inatallation Horizontal / to order Vertical with water supply from below (SAN) or above (FAN) in a special housing
MaterialBrass
Data communicationBuilt-in reed switch pulse transmitter with a multiplicity of 10 liters / pulse
Connection typeCarved / to order Flanged (for DN 20 - DN 40 mm)
Application
  • Heating points
  • Household and industrial accounting
  • Flow converter as part of a mechanical heat meter
  • Other facilities with constant or periodic consumption of hot water, or heat metering (as part of a heat meter) and cold metering (as part of a cold meter) and installation in dry or wet rooms
Features
  • Calibration interval 4 years.
  • Accuracy class 3 according to the Technical Regulations.
  • Counter for measuring the volume of hot water up to 130°C (up to 150°C for one hour per day).
  • Counter for measuring the volume of cold water from +10°C.
  • The degree of protection IP 68 allows you to work in a flooded state, that is, to operate the device both indoors and outdoors (well).
  • The counting mechanism can rotate 350°.
  • Counter installation: horizontal or vertical.
  • High-quality gray cast-iron counter housing.
  • The possibility of connecting a reed pulse transmitter Reed RD022 or an optical pulse transmitter OD.
  • The possibility of connecting the PulseRF radio module + the Reed RD022 reed switch pulse transmitter, which is intended for the integration of counters into the SensusRF wireless radio network for remote data collection.
  • Direct soothing sections are at least 3 x DN before the meter and at least 1 x DN after.