PolluCom FX, F SENSUS

Compact single-channel mechanical heat or cold-heat meter

Brief characteristics
Archives1200 hours, 120 days, 120 months, 500 event records and 500 error messages
Measurement typeMechanical
ConnectionDN 15 - 20 mm
Accuracy class3 (to order 2)
The qp/qi ratio1:25 (on order 1:50 or 1:100)
Water temperature (heat transfer)90 °C (short-term up to 110 °C)
Inatallation Horizontally or vertically
MaterialBrass
BatteryAt least 8 years
Connection typeCarved
Application
  • Apartments
  • Cottages
  • Office premises
  • Shops
  • Warehouses
  • Other objects with constant or periodic consumption of heat or cold-heat metering and installation in dry rooms
Features
  • Calibration interval 4 years.
  • Accuracy class 3 (accuracy class 2 upon request) according to the Technical Regulations.
  • Coolant temperature from +5°C to +90°C (short-term up to +110°C).
  • To order, a model for accounting for cold - heat.
  • The standard delivery is the compact model PolluCom FX (installation of the heat meter on the supply pipeline), on order the compact model PolluCom F (installation of the heat meter on the return pipeline).
  • On request, the PolluCom FX/S and F/S modifications (split - execution) are equipped with a removable heat calculator and a mounting kit for its installation on the wall, the length of the cable between the flow converter and the heat calculator = 0.3 meters.
  • In the standard compact model PolluCom FX or PolluCom F, the heat calculator can rotate around the vertical axis by 330 ° for ease of reading readings.
  • Installation of the heat meter in a horizontal or vertical position.
  • High-quality brass case of the counter.
  • Built-in IrDA optical interface for transmitting information using an optical head to a PC.
  • The amount of heat is displayed on the display in - MWh (megawatt-hours).
  • The length of the thermoconverter cable is 1.5 meters (5 meters upon request).
  • On request, a modification with a built-in M-Bus module (according to EN1434-3) with an unlimited number of readings and configurable telegrams.
  • A modification with a built-in Wireless M-Bus radio module (according to the OMS standard, edition 4.0.2) is available on request.
  • On request, a modification with a built-in M-Bus module (according to EN1434-3) and with two additional inputs for connecting to 2 external counters equipped with a pulse output.
  • A modification with pulse output of thermal energy is available upon request, pulse frequency = 1 kW x hour.
  • Built-in archives (data logger): 1200 hours, 120 days, 120 months, 500 event records and 500 error messages.
  • Autonomous power supply - at least 8 years.
  • Does not require direct calming sections before and after the meter, provided by the length of mounting fittings supplied by the manufacturer in the kit.